RCA CORP, SOLID STATE DIV -- 812A -- 5960-00-552-1107
===================== Product Identification =====================
Product ID:812A
MSDS Date:01/01/1985
FSC:5960
NIIN:00-552-1107
=== Responsible Party ===
Company Name:RCA CORP, SOLID STATE DIV
Address:NEW HOLLAND AVE
City:LANCASTER
State:PA
ZIP:17602
Country:US
CAGE:LO583
=== Contractor Identification ===
Company Name:RCA CORP NEW PRODUCTS DIVISION
Address:NEW HOLLAND AVE
Box:City:LANCASTER
State:PA
ZIP:17602
Country:US
CAGE:26720
Company Name:RCA CORP, SOLID STATE DIV
Address:NEW HOLLAND AVE
Box:City:LANCASTER
State:PA
ZIP:17602
Country:US
CAGE:LO583
============= Composition/Information on Ingredients =============
Ingred Name:THORIUM 232
CAS:7440-29-1
RTECS #:XO6400000
===================== Hazards Identification =====================
Effects of Overexposure:HAZ DEGREE DEPENDS ON TYPE/QUANT OF RADIATION.
LATENT EFFECTS:SOMATIC/GENETIC DAMAGE.
======================= First Aid Measures =======================
First Aid:USE FIRST AID. CALL MEDICAL EMERGENCY CARE. REMOVE/ISOLATE
COMTAMINATED CLOTHING.SHOWER VICTIM(S) W. SOAP & H*2O. DETAIN
PERSONNEL/EQUIPMENT EXPOSED. ADVISE MEDICAL PERSONNEL THAT
VICTIM(S) MAY BE CON TAMINATED.
===================== Fire Fighting Measures =====================
Extinguishing Media:EXTINQUISH W. AGENT SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR CHEMICAL PROTECTIVE SUIT WITH SELF CONTD
BRTHG APP.
Unusual Fire/Explosion Hazard:SOME OF MATL MAY BURN. CONT MAY EXPLODE
IN HEAT OF FIRE.
================== Accidental Release Measures ==================
Spill Release Procedures:HANDLE BROKEN DEVICE WITH GLOVES AND FORCEPS.
====================== Handling and Storage ======================
Handling and Storage Precautions:SHIELD ACCORDING TO EMITTED RADIATION.
PROTECT FROM FILM/FILM PLATES. KEEP CONTAINERS CLOSED. STORE IN
AREA FOR RADIOACTIVE MATERIALS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:SCBA IF INVOLVED IN FIRE, OTHERWISE GAS MASK.
Ventilation:PROVIDE MECHAN(GEN/LOCAL EXHAUST)VENT TO MAINTN